The pressure resistance of PP string wound filter element varies due to many factors. Generally speaking, it has good pressure resistance, but there are also certain range limitations:
1. Conventional pressure resistance level:
When using polypropylene (PP) skeleton, the working pressure of PP string wound filter element is usually around 0.3-0.6MPa, and the maximum pressure resistance generally does not exceed 0.5MPa; the maximum pressure drop is usually around 0.2MPa.
If a stainless steel skeleton is used, the pressure resistance will be relatively higher, and the working pressure can reach 0.5-0.8MPa.
2. Factors affecting pressure resistance:
Skeleton material: The skeleton is the structure that supports the filter element. The stainless steel skeleton has a higher material strength and can withstand higher pressure than the PP skeleton. Therefore, the PP wire wound filter element with a stainless steel skeleton has better pressure resistance.
Winding process: During the production process of the wire wound filter element, the tightness and uniformity of the fiber wire winding will affect its pressure resistance. A filter element that is tightly and evenly wound has a more stable structure and can better withstand pressure; while a filter element that is loosely or unevenly wound may deform or become loose under pressure, affecting its pressure resistance.
Filter element size: Generally speaking, a larger filter element has a larger surface area and is more evenly stressed under the same pressure, so it has better pressure resistance. However, if the filter element is too large, its overall structural strength may be affected by factors such as its own weight, which in turn affects its pressure resistance.
Filter medium: When the filter medium has a high viscosity or contains more impurity particles, it will generate greater resistance and pressure on the filter element during the filtration process, which may reduce the pressure resistance of the filter element. If the filter medium is corrosive, it may also damage the material of the filter element, thereby affecting its pressure resistance.
If you want to know more about the pressure resistance of PP string wound filter elements, please contact ANGE Environmental Technology for more consultation. Our professional team is always on call, willing to listen to your needs and provide you with tailored consultation and guidance.
https://www.angefilter.com/